Objective
To define the operation and cleaning procedures for the octagonal blender.
Scope
This procedure applies to all Production sections of PharmaInfo Ltd.
Responsibility
Production: Executive/Officer/Chemist
Accountability
Head- Production
Procedure
Instrument Detail
Name: OCTAGONAL BLENDER
Make:
Capacity:
Instrument ID.:
Location:
Procedure For Integrity
- To check the cleanliness of the Octagonal blender, remove the “CLEANED EQUIPMENT” status label and Affix the “EQUIPMENT IN USE” label.
- Take line clearance from the IPQA officer.
- Take the telescopic cage in a vertical position.
- Lower the telescopic cage by pressing a button on the operating panel (down).
- Place the filled Bin inside the cage by using a pallet truck and close the railing.
- Lift the telescopic cage by pressing the up button on the operating panel (up).
- Set the blending time & speed (slow/fast) of the blender in PLC.
- Start the blender by touching START in MMI.
- After blending time is over Blender will automatically switch over to creep speed and stop in vertical position.
- To unload the Bin lower down the telescoping cage by pressing the down button provided on the operating panel.
- Place the pallet truck below the Bin and take out the Bin for the next process.
Cleaning of OCTAGONAL BLENDER
1. Type A Cleaning: (Product to Product)
- Clean the Octagonal Bin by using the Bin Wash Assembly or manually and keep in the clean Equipment room.
- Clean the telescopic cage by 100 ltr. potable water until it is visually clean, scrub it with 0.5% teepol solution, and wash with 100 ltr. potable water.
- Rinse the cage finally with 100 liters of purified water.
- Clean the external surface of the Octagonal blender, panel board, railing, and main shaft with wet lint-free cloth and dry with dry lint-free cloth.
- Affix a “CLEANED EQUIPMENT” status label to the blender.
- Maintain record.
2. Type B Cleaning: ( Batch to Batch)
- Dismantle the main switch of the Octagonal blender.
- Without dismantling the machine parts the powder from the previous batch label and material is to be removed and cleaned with clean, dry lint-free cloth.
- Place a “TO BE CLEANED EQUIPMENT” status label on the blender.
- Record the activity in the respective equipment log.
3. Type C Cleaning: (End of the shift)
- Without dismantling the machine parts the powder from the machine is to be removed And cleaned with a clean, dry lint-free cloth at the end of the shift.
- Record the activity in the respective equipment log.
Annexure
Equipment Cleaning Checklist ( Type A)
Equipment Cleaning Checklist ( Type B)
Equipment Cleaning Checklist ( Type C)
Reference
Nil
Abbreviations
SOP - Standard Operating Procedure
QA - Quality Assurance
PR - Production
Revision History
Nil