OBJECTIVE
To provide guidelines for the operation of capsule inspection cum polishing machine.
SCOPE
The procedure outlines the method of operation of the Capsule inspection & Polishing Machine.
MAKE AND CAPACITY
Pacific Technologies
Production Chemist
Production Manager
Operator
PROCEDURE
- Use a Nose mask & rubber gloves while handling the product.
- Fix the product label giving details of the product.
- Load the hopper with Capsules for polishing.
- Adjust the gap between the hopper & inspection plate.
- Start the vacuum pump.
- Start the brush unit & check that it is rotating in a clockwise direction.
- Start the belt.
- Start the vibrator & adjust the rate of flow of capsules by adjusting the vibrator.
- Inspect the capsules visually for broken caps. dented caps as the capsules pass through the inspection belt.
- Pick the rejected capsules & allow only good capsules to enter the polishing unit.
- Collect the polished capsules in airtight containers & store them in a humidity & temperature-controlled area.
PRECAUTION
- Humidity not to exceed 50% + 5% & Temperature 25 deg. C + 2 deg. C.
- Ensure that the Machine is clean before and after use.
- Never put any part of the body in the running machine.
- Use Latex hand gloves and a Mask while handling the product.
REVISION HISTORY
Nil