PURPOSE
To Lay down a procedure for cleaning and sanitization for purified water & Loop system.
SCOPE
This procedure is applicable at PharmaInfo Ltd.
RESPONSIBILITY
Operator/Utility Incharge
ACCOUNTABILITY
Head Quality Assurance
PROCEDURE
Cleaning
- Close the outlet valve of the tank.
- Rub hard the outer and inner surfaces of the tank with a wet lint-free cloth.
- Rinse the outer and inner surface of the tank with a continuous stream of water with the help of a Flexi pipe.
- Pay special attention to hard-to-clean surfaces. IE. vent flow, joints, etc.
- Rinse the inner surface with a continuous stream of water, Drain the dirty water by opening the drain valve.
Sanitisation of Tank and Distribution Line
- Put caution on each user end ‘DO NOT OPEN THE TAP LINE, UNDER SANITIZATION’.
- Heat the water up to 80°C with the use of a heat exchanger.
- Circulate the hot water through the loop system for one hour.
- After completion of sanitization cool the purified water through a heat exchanger and drain.
- After sanitization is complete remove the caution on every user point.
- Inform the user dept. for use of purified water.
Frequency: fortnightly
ANNEXURES
Annexure- 1: Cleaning & Sanitization Record of Purified Water Tank & Distribution Line.
ABBREVIATIONS
SOP: Standard OperatingProcedure
QA: Quality Assurance
REVISION HISTORY
Nil
0 Comments