SOP for Fumigation of Microbiology Laboratory

Objective: 
To lay down a procedure for Fumigation of Microbiology Lab.

Scope:
This SOP shall be applicable to the Microbiology Department of PharmaInfo Ltd.

Responsibility: 
Microbiologist

Accountability: 
Q.C. Manager

Procedure:
  • On the last day of work (weekend) and after completion of all the cleaning activities.
  • Prior to fumigation ensure no trace of water is present in any place.
  • A fumigation container is placed near the door of each room i.e. sterility testing room, and change room.
  • Shut down individual LAF & AHU.
  • Add 20g of potassium permanganate to the fumigation container. Now add 100 ml formaldehyde very slowly and gently to each container.
  • Close the doors.

Abbreviations:
SOP: Standard Operating Procedure
QC: Quality Control
QA: Quality Assurance
AHU: Air Handling Unit
LAF: Laminar Air Flow

Annexure:
Nil

Revision History:
Nil