Objective
To lay down a procedure for Cleaning and sanitation of the Microbiology Lab / sterile room.
Scope
The procedure of this SOP shall be applicable to the Microbiology Department of PharmaInfo Ltd.
Responsibility
Microbiologist
Accountability
Q.C. Manager
Procedure
- After completing work in the Microbiology Laboratory, remove all used and unused material immediately.
- Clean the LAF bench and floor with a dry nylon brush to remove materials; like vials, bungs, aluminum foils, papers, waste media traces and seals etc.
- Collect all the wastes in a plastic tray and transfer them to the dust bean.
- First, mop the floors and the walls of a laboratory with the sanitation solution (Combatant DS) with the help of sterilized nylon cloth.
- Mope the working table with a dry nylon cloth, then clean the table with the suitable detergent (Lanoline 0.5% solution) with the help of a nylon cloth.
- Finally, clean the table with a nylon cloth soaked in sterile water in order to remove the traces of detergents.
- Swab the working table with a suitable disinfectant (Combatant DS) and then by 70% IPA.
- All cleaning and sanitation activities shall be followed by spraying disinfectant. This is applied for disinfection of the air of the area as well as the surface.
- Cleaning Schedule of Microbiology Lab.
|
Mon.
|
Tue.
|
Wed.
|
Thu.
|
Fri.
|
Sat.
|
Pre-Noon Mopping
|
Savlon 2%
|
Dettol 2%
|
Fairgenol 2%
|
B.K.C. 2%
|
Savlon 2%
|
Dettol 2%
|
After
Noon Mopping
|
Dettol 2%
|
Savlon 2%
|
B.K.C. 2%
|
Fairgenol 2%
|
Dettol 2%
|
Savlon 2%
|
Remarks
Spray the area with 70% IPA before 30 mts. of starting the work.
Spray with 2% Lysol daily after completion of work.
Fumigate the on every Saturday as per SOP No. CP/MBS/005
Abbreviations
SOP: Standard Operating Procedure
QC: Quality Control
QA: Quality Assurance
Annexure
Nil
Revision History
Nil